N2 - In this paper, a scheme is proposed to monitor the weak voltage load bus groups with Thevenin equivalent parameters. First, continuation power flow solves V - λ curves of the load buses. Then weak voltage buses are selected with voltage magnitude variation under similar load variation rate. The buses of bigger normalized ΔV are chosen as weak voltage ones. The rate of voltage magnitude variation is used as grouping standard and an index is constructed for weak voltage load bus group similarity. A fuzzy maximal tree is established to group the weak voltage load buses according to their similarities and simultaneously the geographic factors are taken into consideration. We track network side Thevenin equivalent parameters on each typical bus of weak voltage load bus group and analyze the problems of Thevenin equivalent parameters computing based on local measurements. Therefore, a power flow data based simulation method to track Thevenin equivalent parameters is presented, which can observe the voltage stability margin of weak voltage load bus group. The simulations on IEEE 118 bus system show our scheme is effective.
AB - In this paper, a scheme is proposed to monitor the weak voltage load bus groups with Thevenin equivalent parameters. First, continuation power flow solves V - λ curves of the load buses. Then weak voltage buses are selected with voltage magnitude variation under similar load variation rate. The buses of bigger normalized ΔV are chosen as weak voltage ones. The rate of voltage magnitude variation is used as grouping standard and an index is constructed for weak voltage load bus group similarity. A fuzzy maximal tree is established to group the weak voltage load buses according to their similarities and simultaneously the geographic factors are taken into consideration. We track network side Thevenin equivalent parameters on each typical bus of weak voltage load bus group and analyze the problems of Thevenin equivalent parameters computing based on local measurements. Therefore, a power flow data based simulation method to track Thevenin equivalent parameters is presented, which can observe the voltage stability margin of weak voltage load bus group. The simulations on IEEE 118 bus system show our scheme is effective.
KW - Fuzzy maximal tree clustering
KW - Power flow
KW - Tracking of Thevenin equivalent parameters
KW - Typical bus of weak voltage load bus group
KW - Weak voltage load buses grouping
UR - https://www.scopus.com/pages/publications/69049108395
U2 - 10.1109/PSCE.2006.296147
DO - 10.1109/PSCE.2006.296147
M3 - 会议稿件
AN - SCOPUS:69049108395
SN - 142440178X
SN - 9781424401789
T3 - 2006 IEEE PES Power Systems Conference and Exposition, PSCE 2006 - Proceedings
SP - 1570
EP - 1576
BT - 2006 IEEE PES Power Systems Conference and Exposition, PSCE 2006 - Proceedings
T2 - 2006 IEEE PES Power Systems Conference and Exposition, PSCE 2006
Y2 - 29 October 2006 through 1 November 2006
ER -