TH‐E‐L100J‐04: Calibration of Bent‐Ray Ultrasound Tomography and Its Application to Breast Cancer Detection and Diagnosis

  • Wayne State University
  • Los Alamos National Laboratory

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Travel‐time tomography plays a central role in our current ring transducer array (Computerized Ultrasound Risk Evaluation — CURE) study of patients with suspicious breast masses. To properly calibrate an algorithm used for bent‐ray tomographic inversion of clinical ultrasound data, the following issues need to be addressed: balancing the data contribution and an a priori model, determining the stopping criteria for the iteration of the inversion, and estimating the resolving power of the tomography algorithm, that is, determining the reliability of the inversion. Method and Materials: In this study, quantitative assessments of the above issues are made based on synthetic models. The simulated ultrasonic data are generated using a high‐order finite‐difference time‐domain acoustic‐wave equation to model wave propagation through different numerical breast phantoms. The breast models are obtained by digitizing the reconstructed images of patient data and phantom data scanned by the CURE device. Checkerboard and perturbation tests are also performed to provide a quantitative estimate of the resolving power of the bent‐ray tomography algorithm. Guided by the synthetic study, the tomography algorithm with optimum parameters is applied to in‐vivo patient data acquired using CURE for breast cancer detection and diagnosis. Results: Our series of synthetic simulations show that an optimum trade‐off parameter can be chosen effectively using L‐Curve analysis. In addition, the stopping criteria can be chosen based on convergence rates of the iteration. Checkerboard and perturbation tests set a quantitative upper limit of the resolving power of the bent‐ray tomography for ultrasound data acquired with a ring array. Conclusion: Calibration of the bent‐ray tomography algorithm provides a high degree of confidence in tomographic inversion results, and helps in obtaining optimal tomographic images from in‐vivo ultrasound breast data.

Original languageEnglish
Pages (from-to)2645
Number of pages1
JournalMedical Physics
Volume34
Issue number6
DOIs
StatePublished - Jun 2007
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'TH‐E‐L100J‐04: Calibration of Bent‐Ray Ultrasound Tomography and Its Application to Breast Cancer Detection and Diagnosis'. Together they form a unique fingerprint.

Cite this