Abstract
Production of battery brings a lot of wastewater which contains heavy metal Pb, the spent sulfuric acid, some refractory organic pollutants and domestic wastewater. The optimal operating conditions are as following: [H 2O 2]=600 mg/L, [FeSO 4·7H 2O]=2.0 g/L, 20°C and 30 min at pH=3.0. Under these conditions, the COD removal are 87.6%, COD<100 mg/L and the heavy metal Pb has not picked out, which reaches the national emission standard.
| Original language | English |
|---|---|
| Pages (from-to) | 17-20 |
| Number of pages | 4 |
| Journal | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology |
| Volume | 44 |
| Issue number | SUPPL.2 |
| State | Published - Mar 2012 |
Keywords
- Coagulation
- Fenton
- Mn
- Pb
- Refractory organic pollutants
Fingerprint
Dive into the research topics of 'The study on the treatment of battery wastewater by fenton process'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS