title = "The image reconstruction of electrical capacitance tomography: With the FE simulation data",
abstract = "Electrical capacitance tomography (ECT) was one of firstly developed for process tomography. This paper describe a method for image reconstruction with electrical capacitance tomography using a finite-element model to solve the forward problem. A finite element model of 8-pole capacitance tomography sensor is set up with the software ANSYS, the sensitivity map is calculated with the simulation data, and the image is reconstructed with linear back projections, Landwber iteration and Tikhonov regularization method, the image quality was evaluated with image error.",
keywords = "Capacitance tomography, Finite element, Image reconstruction",
author = "Min Zhao and Zhang, \{Dong Lai\} and Zhihui Zhou",
note = "Publisher Copyright: {\textcopyright} International Society for Industrial Process Tomography, 2010. All rights reserved.; 6th World Congress in Industrial Process Tomography ; Conference date: 06-09-2010 Through 09-09-2010",
year = "2010",
language = "英语",
series = "6th World Congress in Industrial Process Tomography",
publisher = "International Society for Industrial Process Tomography",
pages = "1082--1088",
booktitle = "6th World Congress in Industrial Process Tomography",
}