Skip to main navigation Skip to search Skip to main content

Terahertz computed tomography using a continuous-wave gas laser

  • Qi Li*
  • , Yun Da Li
  • , Sheng Hui Ding
  • , Qi Wang
  • *Corresponding author for this work
  • Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

A 3D continuous-wave (CW) terahertz computed tomography (CT) system employing a gas laser operating at 2.52 THz is presented. To shorten acquisition time on the premise of guaranteeing the image quality, the modified simultaneous algebraic reconstruction technique (MSART) coupled with image processing operations like the Gaussian low-pass filter (GLPF), open operation and close operation has been adopted in the paper. With the 2D results the 3D images of the samples have been also obtained. The reconstruction results illustrate the promising application prospects of this CW THz CT system.

Original languageEnglish
Pages (from-to)548-558
Number of pages11
JournalJournal of Infrared, Millimeter, and Terahertz Waves
Volume33
Issue number5
DOIs
StatePublished - May 2012

Keywords

  • Gas laser
  • Image processing
  • Terahertz
  • Tomographic imaging

Fingerprint

Dive into the research topics of 'Terahertz computed tomography using a continuous-wave gas laser'. Together they form a unique fingerprint.

Cite this