Skip to main navigation Skip to search Skip to main content

Temperature dissipation measurements in a fully developed turbulent channel flow

  • Y. Zhu*
  • , R. A. Antonia
  • *Corresponding author for this work
  • University of Newcastle

Research output: Contribution to journalArticlepeer-review

Abstract

All three derivatives of the temperature fluctuation θ in a fully developed turbulent channel flow have been measured using a pair of parallel cold wires with fixed separations in either the x (streamwise), y (normal to the wall) or z (spanwise) direction. At several locations, measurements were also made, each for a range of y separations between the wires. These latter measurements were important for establishing a suitable method of correcting the data for the effect of wire separation, thus allowing the fixed separation data to be corrected. In the near-wall region, the corrected temperature dissipation is in good agreement with results from direct numerical simulations. The time scale ratio deduced from measurements and simulations agrees well with the theoretical wall value.

Original languageEnglish
Pages (from-to)191-199
Number of pages9
JournalExperiments in Fluids
Volume15
Issue number3
DOIs
StatePublished - Aug 1993
Externally publishedYes

Fingerprint

Dive into the research topics of 'Temperature dissipation measurements in a fully developed turbulent channel flow'. Together they form a unique fingerprint.

Cite this