@inproceedings{1659286ad64640019abe4df68782e826,
title = "Study on measurement of oil gas water three phase flow with conductance correlative flow meter",
abstract = "Since oil gas water three phase flow is a complex process, it is quite difficult to measure its parameters. Most of single phase flow meters do not fit for three phase. A conductance correlative flow meter is studied for three phase flow measurement. The experiment results show that this method is feasible. And the applying technique conditions are that water volume ratio of liquid is more than 50\%, gas volume ratio is less than 40\% , and the flow rate is not less than 1m/s. Under the conditions, the maximum measure error is less than ±5\%.",
keywords = "Conductance, Correlative, Measurement, Oil gas water, Three phase flow",
author = "Guomin Xue and Yi Shen",
year = "2008",
doi = "10.1109/ICAL.2008.4636352",
language = "英语",
isbn = "9781424425020",
series = "Proceedings of the IEEE International Conference on Automation and Logistics, ICAL 2008",
pages = "1295--1297",
booktitle = "Proceedings of the IEEE International Conference on Automation and Logistics, ICAL 2008",
note = "IEEE International Conference on Automation and Logistics, ICAL 2008 ; Conference date: 01-09-2008 Through 03-09-2008",
}