Abstract
The temperature fields of non-slotted and slotted light steel-framed composite walls have been simulated using the finite element software of ANSYS. The thermal performances of the walls with different web-perforated types, frame types, thickness of exterior insulation layer are calculated. The thermal performance of the composite walls with web-perforated has been tested using the Combined Energy Consumption Test Board for Components of Building Envelope. The simulated results fit to the experimental results. This shows that the model of the three-dimensional heat transfer set up in the paper is right and the simulated results are believable.
| Original language | English |
|---|---|
| Pages (from-to) | 63-66 |
| Number of pages | 4 |
| Journal | Journal of Harbin Institute of Technology (New Series) |
| Volume | 14 |
| Issue number | SUPPL. |
| State | Published - Jan 2007 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Heat transfer
- Numerical simulation
- Slotted light steel-framed composite wall
- Thermal bridge
Fingerprint
Dive into the research topics of 'Study on heat transfer of light steel-framed composite walls in cold area'. Together they form a unique fingerprint.Cite this