Abstract

In view of the issue that Heat Conductivity Coefficient (HCC) value of Thick-typed Fireproofing Coating (TFC) for tunnel at elevated temperature is not unknown, which makes researchers unable to make right fireproofing design and analysis for structure, starting from composition of TFC for tunnel, regarding it as complex of insulation aggregate and adhesive material, and using series model and parallel model, formulas of HCC at elevated temperature are established. The temperature field in three specimens is calculated by above HCC value, and is compared with testing results. Analysis result shows that HCC value from series model is the most reasonable. This paper provides an effective Solution for HCC value of TFC for tunnel at elevated temperature.

Original languageEnglish
Title of host publicationApplied Mechanics and Materials I
Pages2103-2106
Number of pages4
DOIs
StatePublished - 2013
Externally publishedYes
Event2012 International Conference on Applied Mechanics and Materials, ICAMM 2012 - Sanya, China
Duration: 24 Nov 201225 Nov 2012

Publication series

NameApplied Mechanics and Materials
Volume275-277
ISSN (Print)1660-9336
ISSN (Electronic)1662-7482

Conference

Conference2012 International Conference on Applied Mechanics and Materials, ICAMM 2012
Country/TerritoryChina
CitySanya
Period24/11/1225/11/12

Keywords

  • Complex
  • Elevated temperature
  • Heat conductivity coefficient
  • Model
  • Thick-typed fireproofing coating for tunnel

Fingerprint