Abstract
In high-speed aircraft, an altitude adjustment system is an important auxiliary part that needs rapid power support. In this paper, an ultrahigh-speed generator is described. However, the ultrahigh-speed generator's safe operation and smooth power supply to the load can be threatened by mismatch between the open-loop generator and fickle load conditions. In this study, a power converter with a paralleled energy-matching link was developed, which can broaden the safe operation zone and ensure the generator's safe operation as well as the load's smooth power supply under relatively light-load conditions. This power converter can also ensure the power supply voltage under relatively heavy-load conditions. The validity of the proposed power converter was verified by experiments.
| Original language | English |
|---|---|
| Article number | 7502138 |
| Pages (from-to) | 5112-5120 |
| Number of pages | 9 |
| Journal | IEEE Transactions on Industry Applications |
| Volume | 52 |
| Issue number | 6 |
| DOIs | |
| State | Published - 1 Nov 2016 |
| Externally published | Yes |
Keywords
- Energy matching
- qualitative modeling
- ultrahigh-speed generator
Fingerprint
Dive into the research topics of 'Study on Energy Matching Methods for Ultrahigh-Speed Generator System Based on Qualitative Modeling Analysis'. Together they form a unique fingerprint.Cite this