Skip to main navigation Skip to search Skip to main content

Study of magnetoelastic behavior of Terfenol-D under low frequency and low strength magnetic fields for alternating magnetic field measurements

Research output: Contribution to journalArticlepeer-review

Abstract

Terfenol-D is a magnetostrictive material well known for its large magnetostriction and high magnetic flux density which makes it suitable for a wide range of sensing and actuation applications. This paper is based on experimental study performed to analyze the magnetoelastic vibrations produced within Terfenol-D when exposed to low strength time varying magnetic fields ranging between 60 Hz and 1 KHz. The vibrations produced within Terfenol D due to time varying magnetic fields were observed using a high-speed laser vibrometer. The results obtained demonstrate excellent response of Terfenol-D and validate its feasibility for using this material in magnetoelastic devices for low frequency and low strength time varying magnetic fields measurements associated with various engineering and scientific applications.

Original languageEnglish
Pages (from-to)77-79
Number of pages3
JournalMaterials Letters
Volume240
DOIs
StatePublished - 1 Apr 2019
Externally publishedYes

Keywords

  • Magnetic field
  • Magnetic materials
  • Magnetostriction
  • Sensors

Fingerprint

Dive into the research topics of 'Study of magnetoelastic behavior of Terfenol-D under low frequency and low strength magnetic fields for alternating magnetic field measurements'. Together they form a unique fingerprint.