title = "Structure and mainly performance test analysis of the new pattern stainless steel multilayer corrugated tube",
abstract = "The structure and performance test analysis of the new pattern stainless steel multilayer corrugated tube were discussed. The performance testing was done after the installation of the tube at middle condenser of the compressor. The results demonstrated the tube to be safe and reliable in structure and energy-saving.",
keywords = "Corrugated tube heat exchanger, Mainly performance test, Multilayer corrugated tube, Special stainless steel plate material, Structure",