Skip to main navigation Skip to search Skip to main content

Some measurements of electromagnetic forming

  • Zhong Li*
  • , Chun Feng Li
  • , Zhi Heng Zhao
  • *Corresponding author for this work
  • Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Some methods to measure discharging current, the magnetic induction intensity and are presented and discussed, by theoretical analysis and comparison, some conclusions are drawn. Measuring discharging current with current divider and measuring magnetic induction intensity with magnetic test coil are feasible in practice. Deformation behavior of work-piece under electromagnetic force can be measured with sliding needles and high-speed camera, each method has advantages and disadvantages, according to the specific experimental situation, the more appropriate method should be chosen.

Original languageEnglish
Pages (from-to)81-84
Number of pages4
JournalSuxing Gongcheng Xuebao/Journal of Plasticity Engineering
Volume11
Issue number4
StatePublished - Aug 2004

Keywords

  • Current divider
  • Electromagnetic force
  • High-speed camera
  • Magnetic test coil
  • Sliding needles

Fingerprint

Dive into the research topics of 'Some measurements of electromagnetic forming'. Together they form a unique fingerprint.