Skip to main navigation Skip to search Skip to main content

Simultaneous identification of joint stiffness, kinematic and hand-eye parameters of measurement system integrated with serial robot and 3D camera

  • Jinlei Zhuang
  • , Ruifeng Li*
  • , Chuqing Cao
  • , Yunfeng Gao
  • , Ke Wang
  • , Feiyang Wang
  • *Corresponding author for this work
  • Harbin Institute of Technology Shenzhen
  • HIT Wuhu Robot Technology Research Institute

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: This paper aims to propose a measurement principle and a calibration method of measurement system integrated with serial robot and 3D camera to identify its parameters conveniently and achieve high measurement accuracy. Design/methodology/approach: A stiffness and kinematic measurement principle of the integrated system is proposed, which considers the influence of robot weight and load weight on measurement accuracy. Then an error model is derived based on the principle that the coordinate of sphere center is invariant, which can simultaneously identify the parameters of joint stiffness, kinematic and hand-eye relationship. Further, considering the errors of the parameters to be calibrated and the measurement error of 3D camera, a method to generate calibration observation data is proposed to validate both calibration accuracy and parameter identification accuracy of calibration method. Findings: Comparative simulations and experiments of conventional kinematic calibration method and the stiffness and kinematic calibration method proposed in this paper are conducted. The results of the simulations show that the proposed method is more accurate, and the identified values of angle parameters in modified Denavit and Hartenberg model are closer to their real values. Compared with the conventional calibration method in experiments, the proposed method decreases the maximum and mean errors by 19.9% and 13.4%, respectively. Originality/value: A new measurement principle and a novel calibration method are proposed. The proposed method can simultaneously identify joint stiffness, kinematic and hand-eye parameters and obtain not only higher measurement accuracy but also higher parameter identification accuracy, which is suitable for on-site calibration.

Original languageEnglish
Pages (from-to)484-493
Number of pages10
JournalIndustrial Robot
Volume48
Issue number4
DOIs
StatePublished - 2021
Externally publishedYes

Keywords

  • 3D
  • Calibration
  • Hand-eye calibration
  • Joint stiffness
  • Robot integrated system
  • Simultaneous calibration

Fingerprint

Dive into the research topics of 'Simultaneous identification of joint stiffness, kinematic and hand-eye parameters of measurement system integrated with serial robot and 3D camera'. Together they form a unique fingerprint.

Cite this