Abstract
In order to balance the contradiction between the demand of high precision and that of short time interval of model computing for the power plant simulator, a set of simulated mathematical models are constructed. The model describes the cylinder wall temperature located at four key positions of the high pressure cylinder. The simulated model is confirmed to be not only simple but also precise via comparison between the simulated results and the autoptic data of a power plant.
| Original language | English |
|---|---|
| Pages (from-to) | 442-445 |
| Number of pages | 4 |
| Journal | Chinese Journal of Mechanical Engineering (English Edition) |
| Volume | 18 |
| Issue number | 3 |
| DOIs | |
| State | Published - Sep 2005 |
Keywords
- Cylinder wall temperature
- Mathematical model
- Simulation
- Turbine
Fingerprint
Dive into the research topics of 'Simulated mathematical model for high pressure cylinder wall temperature of homemade turbine'. Together they form a unique fingerprint.Cite this