Abstract

Resonant fiber optic gyro (RFOG) is a type of inertial sensor with great application potential. Its closed-loop signal detection methods include single closed-loop, double closed-loop and other methods to ensure high system stability and high-precision signal output. In view of the respective advantages of single and double closed-loop systems, a single-double interval closed-loop scheme for RFOG is proposed in this letter. By introducing the threshold trigger mechanism, the advantages of low control signal noise of the single closed-loop system and large dynamic range of the double closed-loop system are fully combined. In addition, in order to improve the linearity of the demodulation curve, a linear fitting method is applied to the system. The experiment shows that the short-term and long-term stability of the system have been improved effectively.

Original languageEnglish
Pages (from-to)132-135
Number of pages4
JournalIEEE Photonics Technology Letters
Volume35
Issue number3
DOIs
StatePublished - 1 Feb 2023
Externally publishedYes

Keywords

  • RFOG
  • closed-loop method
  • linear fitting
  • single-double interval closed-loop

Fingerprint

Dive into the research topics of 'Research on the Single-Double Interval Closed-Loop Method of Resonant Fiber Optic Gyro'. Together they form a unique fingerprint.