Research on Do-Not-Disturb Technology for Substation Reconstruction and Expansion Based on Panoramic Model

  • Dongqing He*
  • , Zhexue Zou
  • , Yulong Pei
  • , Chuanyu Zhang
  • , Kun Wang
  • , Zhongyu Ye
  • , Lu Ju
  • , Yuanyuan Li
  • *Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Proposing a do-not-disturb method for substation monitoring system reconstruction and expansion based on panoramic model data. During the initial construction of the substation, the panoramic model data of the entire substation is drawn according to the long-term scale, including the line bays to be expanded. Soft pressure plate signals are added to each bay model of the entire substation to determine whether they participate in logical operations. The monitoring backend draws and transmits the database, graphic images, sequence control tickets, five prevention interlocking, reports, and forwarding tables at once based on the panoramic integrated model data, and performs panoramic interlocking logic configuration for cross bay measurement and protection equipment; The monitoring backend calculates the input or output status of the soft pressure plate based on the bay model logic to determine whether to set the current bay data to a valid state. The measurement and protection equipment calculates the input or output status of the soft pressure plate based on the cross bay and ontology bay logic to determine whether the corresponding interlocking signal of the bay is participating in the logical operation normally. Through the above methods, the operational risk of the Substation expansion work is reduced and the expansion workload is reduced.

Original languageEnglish
Title of host publication2024 11th International Forum on Electrical Engineering and Automation, IFEEA 2024
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages569-572
Number of pages4
ISBN (Electronic)9798331516611
DOIs
StatePublished - 2024
Externally publishedYes
Event11th International Forum on Electrical Engineering and Automation, IFEEA 2024 - Shenzhen, China
Duration: 22 Nov 202424 Nov 2024

Publication series

Name2024 11th International Forum on Electrical Engineering and Automation, IFEEA 2024

Conference

Conference11th International Forum on Electrical Engineering and Automation, IFEEA 2024
Country/TerritoryChina
CityShenzhen
Period22/11/2424/11/24

Keywords

  • component
  • do-not-disturb
  • monitoring system
  • panoramic model data
  • soft platen signal

Fingerprint

Dive into the research topics of 'Research on Do-Not-Disturb Technology for Substation Reconstruction and Expansion Based on Panoramic Model'. Together they form a unique fingerprint.

Cite this