Skip to main navigation Skip to search Skip to main content

Research on corrosion mechanism of water distribution system

  • Xin Yu Zhang*
  • , Xin Li
  • , Wu Qin
  • , Wen Wen Xu
  • , Yi Xing Yuan
  • *Corresponding author for this work
  • Harbin Institute of Technology
  • University of Jinan
  • School of Chemistry and Chemical Engineering, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Pipes serving for water distribution system for different years in northern city, were chosen as objectives for study. The shape and component of corrosion scales were measured, and formation mechanism of corrosion was also analyzed. The corrosion mechanism of pipes was studied on the sides of electrochemistry and microbe. The solution to eliminate corrosion scales in water distribution system was also proposed. The results show that the specific surface areas of five corrosion scales are between 41.35 and 132.3 m2/g and the dimension of corrosion scales enlarge with the increase of serving age, which could induce the decrease of water flow cross-section.

Original languageEnglish
Pages (from-to)121-125
Number of pages5
JournalJournal of Harbin Institute of Technology (New Series)
Volume18
Issue number1
StatePublished - Feb 2011
Externally publishedYes

Keywords

  • Corrosion
  • Water distribution system
  • Water quality

Fingerprint

Dive into the research topics of 'Research on corrosion mechanism of water distribution system'. Together they form a unique fingerprint.

Cite this