Skip to main navigation Skip to search Skip to main content

Rapid and sensitive detection of Amphidinium carterae by loop-mediated isothermal amplification combined with a chromatographic lateral-flow dipstick

  • School of Marine Science and Technology, Harbin Institute of Technology Weihai
  • School of Environment, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Frequent outbreaks of toxic algal blooms devastate marine ecosystems, marine fisheries, and public health. Monitoring toxic algae is crucial to reduce losses caused by imminent algal blooms. However, traditional detection techniques relying on morphological examination are tedious and time-consuming. Therefore, the development of convenient strategies to detect toxin-producing microalgae is necessary. In this study, a novel method for the rapid, sensitive detection of Amphidinium carterae by loop-mediated isothermal amplification (LAMP) combined with a chromatographic lateral-flow dipstick (LFD) was established. The partial internal transcribed spacer gene was PCR amplified, cloned, and sequenced to design four LAMP primers and a detection probe for A. carterae detection. The LAMP detection conditions were optimized, and the optimum parameters were determined to be the following: dNTP concentration, 1.2 mM; betaine concentration, 1.2 M; magnesium ion concentration, 8 mM; ratio of inner primer to outer primer, 8:1; amplification temperature, 59 °C; and amplification time, 60 min. The specificity of LAMP-LFD was confirmed by cross-reactivity tests with other algal species. LAMP-LFD was 100 times more sensitive than regular PCR and similarly sensitive as LAMP and SYBR Green I. LAMP-LFD can be completed within 70 min and did not require special detection equipment. The convenience of the established LAMP-LFD assay was further validated by tests with simulated field-water samples. In conclusion, the developed LAMP-LFD assay can be used as a reliable and simple method of detecting A. carterae.

Original languageEnglish
Pages (from-to)72-79
Number of pages8
JournalMolecular and Cellular Probes
Volume43
DOIs
StatePublished - Feb 2019
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 14 - Life Below Water
    SDG 14 Life Below Water

Keywords

  • Amphidinium carterae
  • Detection
  • Loop-mediated isothermal amplification combined with a chromatographic lateral-flow dipstick

Fingerprint

Dive into the research topics of 'Rapid and sensitive detection of Amphidinium carterae by loop-mediated isothermal amplification combined with a chromatographic lateral-flow dipstick'. Together they form a unique fingerprint.

Cite this