Skip to main navigation Skip to search Skip to main content

Quantitively Analyzing the Variation of Micrometer-Sized Microplastic during Water Treatment with the Flow Cytometry- Fluorescent Beads Method

  • Xian Shi Wang
  • , Heng Song
  • , Yu Lei Liu
  • , Xiang Rui Pan
  • , Hao Chen Zhang
  • , Zhi Gao
  • , De Zhen Kong
  • , Rui Wang
  • , Lu Wang*
  • , Jun Ma
  • *Corresponding author for this work
  • School of Environment, Harbin Institute of Technology
  • Qingdao Agricultural University

Research output: Contribution to journalArticlepeer-review

Abstract

Microplastic pollution has aroused surging concerns, while methods for quantitively analyzing the removal of microplastic in water treatment are insufficient. Herein, a flow cytometry (FCM)-fluorescent beads (FB) method was developed for evaluating the removal of micrometer-sized microplastic in water treatment. Commercial fluorescently labeled polystyrene beads (Φ = 3 μm) were spiked into water to mimic microplastic, and FCM was used for quantitive determination. The coefficient of determination (R2) of the amount of spiked microplastics and detected signals in pure water, surface water, and wastewater treatment plant effluent surpassed 0.99. For the removal of microplastics by different coagulants (50 mg/L) at pH 7.0, the removal ratio of microplastics by FeCl3 and polyaluminum chloride was significantly higher than that by polyferric sulfate, alum, Al2(SO4)3, and FeSO4. Over 85% of the polystyrene beads (1.5 × 105 pieces/L) were removed by 50 mg/L of FeCl3 or polyaluminum chloride, and the removal effect was correlated with the size of the floc formed in the hydrolyzation of the coagulants. Filtration was less effective for the removal of microplastics, and the removal efficiency was below 66% when using six kinds of conventional filter materials. Ferrate oxidation was more effective for microplastic removal, as over 93.7% of polystyrene beads (1.5 × 105 pieces/L) were removed by 5 mg/L of ferrate (as Fe) at pH 7.0. The FCMFB method can be a paradigm for studying the removal of micrometer-sized microplastics in water treatment procedures.

Original languageEnglish
Pages (from-to)1668-1677
Number of pages10
JournalACS ES and T Engineering
Volume1
Issue number12
DOIs
StatePublished - 10 Dec 2021
Externally publishedYes

Keywords

  • flow cytometry
  • fluorescent beads
  • microplastics
  • quantitative analysis
  • water treatment

Fingerprint

Dive into the research topics of 'Quantitively Analyzing the Variation of Micrometer-Sized Microplastic during Water Treatment with the Flow Cytometry- Fluorescent Beads Method'. Together they form a unique fingerprint.

Cite this