Precise Calculation Method of Vector Dwell Times for Single-Stage Isolated Three-Phase Buck-Type Rectifier to Reduce Grid Current Distortions

Research output: Contribution to journalArticlepeer-review

Abstract

Since the dc side current of the single-stage isolated three-phase buck-Type rectifier (1S-ITBR) is discontinuous, the conventional current space vector pulsewidth modulation presents a poor grid current characteristics. In this article, the expressions of the instantaneous grid current of 1S-ITBR and the amplitudes of various-order grid current harmonics are originally derived. These results reveal the essential reason for causing t low-order current harmonics. Then, the improved calculation method of dwell times of the effective current space vectors with the goal of eliminating the grid current distortion is proposed to improve the grid current quality. The correctness of the harmonics analysis and the feasibility and validity of the proposed improved method are experimentally verified.

Original languageEnglish
Article number8796383
Pages (from-to)4457-4466
Number of pages10
JournalIEEE Journal of Emerging and Selected Topics in Power Electronics
Volume8
Issue number4
DOIs
StatePublished - Dec 2020

Keywords

  • Current harmonics
  • isolated buck-Type rectifier
  • vector dwell time calculation

Fingerprint

Dive into the research topics of 'Precise Calculation Method of Vector Dwell Times for Single-Stage Isolated Three-Phase Buck-Type Rectifier to Reduce Grid Current Distortions'. Together they form a unique fingerprint.

Cite this