Plasma immersion ion implantation into inner surfaces of tubes has practical importance, but intrinsic drawbacks such as poor dose uniformity and small equivalent ion flux have limited wider applications. In this paper, a new technique utilizing a moving auxiliary electrode inside the tube to improve the dose uniformity and ion implantation efficiency is described. The effects of the moving auxiliary electrode are investigated by 2-D particle-in-cell simulation. The results show that, when the grounded auxiliary electrode is withdrawn along the axis of the tube, external ions are continuously attracted into the tube and implanted into the interior wall. It is verified by the incident dose peak when the auxiliary electrode is kept at a certain location inside the tube. Uniform ion implantation into a cylindrical bore can be accomplished by physical translation of the electrode, and this technique is suitable for implantation of long tubes without an internal plasma source.

Original languageEnglish
Article number6044725
Pages (from-to)3120-3124
Number of pages5
JournalIEEE Transactions on Plasma Science
Volume39
Issue number11 PART 2
DOIs
StatePublished - Nov 2011
Externally publishedYes

Keywords

  • Moving auxiliary electrode
  • numerical simulation
  • particle-in-cell (PIC)
  • plasma immersion ion implantation (PIII)

Fingerprint

Dive into the research topics of 'Plasma immersion ion implantation into inner surface of cylindrical bore using moving auxiliary electrode'. Together they form a unique fingerprint.

Cite this