TY - GEN
T1 - Parametric study of crowned blade in horizontal axial turbine
AU - Zhou, Jun Wei
AU - Wang, Da Zheng
PY - 2013
Y1 - 2013
N2 - The horizontal axial turbine could extract kinetic energy from both wind and tidal stream. In this paper, a type of horizontal axial turbine was designed with a crown stalled on the blade tip and the turbine was analyzed in a tidal stream. Several turbines with different geometries of the crowns were compared, whose power coefficients were numerically simulated by the CFD method. Effects of the crown design parameters, such as crown setting directions and different widths on turbine efficiency were discussed. Furthermore, when the turbine worked at different tip speed ratio, the results were discussed, either. By analysis of the results, it is could be concluded that a circular crown was sufficient to eliminate blade tip loss caused by tip leakage flow. The upstream semicircle crown modified the corresponding side foil pressure distribution to the design value, and so did the downstream semicircle crown. In the ellipse crowns testing, turbine efficiency was approximately in line with the value of crowns width. When the turbine with the circular crown worked at a little higher tip speed ratio than the design value, the crown was effective as before.
AB - The horizontal axial turbine could extract kinetic energy from both wind and tidal stream. In this paper, a type of horizontal axial turbine was designed with a crown stalled on the blade tip and the turbine was analyzed in a tidal stream. Several turbines with different geometries of the crowns were compared, whose power coefficients were numerically simulated by the CFD method. Effects of the crown design parameters, such as crown setting directions and different widths on turbine efficiency were discussed. Furthermore, when the turbine worked at different tip speed ratio, the results were discussed, either. By analysis of the results, it is could be concluded that a circular crown was sufficient to eliminate blade tip loss caused by tip leakage flow. The upstream semicircle crown modified the corresponding side foil pressure distribution to the design value, and so did the downstream semicircle crown. In the ellipse crowns testing, turbine efficiency was approximately in line with the value of crowns width. When the turbine with the circular crown worked at a little higher tip speed ratio than the design value, the crown was effective as before.
KW - Crowned blade
KW - Horizontal axial turbine
KW - Parametric study
UR - https://www.scopus.com/pages/publications/84884774783
U2 - 10.4028/www.scientific.net/AMR.732-733.443
DO - 10.4028/www.scientific.net/AMR.732-733.443
M3 - 会议稿件
AN - SCOPUS:84884774783
SN - 9783037857434
T3 - Advanced Materials Research
SP - 443
EP - 450
BT - Thermal, Power and Electrical Engineering
T2 - 2013 2nd International Conference on Energy and Environmental Protection, ICEEP 2013
Y2 - 19 April 2013 through 21 April 2013
ER -