@inproceedings{2aa5a1b49e05419e9977f3f9b17ebdf5,
title = "Optimization of the alternate cycle in a membrane aeration/filtration combined bioreactor",
abstract = "In this study, a membrane aeration/filtration combined bioreactor (CMBR) was constructed, and the effect of alternate cycle by CMBR on membrane fouling and oxygen utilization efficiency (OUE) was investigated. Results showed that under the condition, when the alternate cycle was 0.75-3h, the ΔTMP (TMP value of the time when a filtration cycle was over) of CMBR maintained a basically constant value during the 6 days' continuous operation, which implied the CMBR achieved a favorable effect of the membrane fouling relieving. Too short or too long cycle would lead to a gradual increase of ΔTMP. OUE of CMBR increased with the extension of the alternate cycle. Thus, it suggested that the optimal alternate cycle of CMBR should be 3h.",
keywords = "Alternate cycle, Membrane aeration/filtration combined bioreactor, Membrane fouling, Oxygen utilization efficiency",
author = "Hongjie Wang and Wenyi Dong and Yue Yang and Guanghua Gan and Weiguang Li",
year = "2010",
doi = "10.1063/1.3456294",
language = "英语",
isbn = "9780735407985",
series = "AIP Conference Proceedings",
pages = "121--124",
booktitle = "2nd International Symposium on Aqua Science, Water Resource and Low Carbon Energy",
note = "2nd International Symposium on Aqua Science, Water Resource and Low Carbon Energy ; Conference date: 07-12-2009 Through 10-12-2009",
}