TY - GEN
T1 - Open-Circuit Diagnosis of Dual-Redundancy Permanent Magnet Synchronous Motor Based on Voltage Disturbance Observer
AU - Wang, Shuai
AU - Yang, Guijie
AU - Su, Jianyong
N1 - Publisher Copyright:
© 2023 IEEE.
PY - 2023
Y1 - 2023
N2 - Dual Redundancy Permanent Magnet Synchronous Motor (DR-PMSM) has been widely used in the aviation electrical actuation system, the two sets of windings of DR-PMSM are independently driven by two inverters with isolated bus. When one set of winding or inverter fails, the other set of winding and inverter can work normally. However, the two sets of windings of DR-PMSM share one stator, which leads to strong coupling between the two sets of windings. In order to realize open-circuit fault (OCF) diagnosis of DR-PMSM, voltage disturbance observer of decoupled virtual current loops is designed. The voltage disturbance is observed with four luenberger observers of virtual current loops, the estimated voltage disturbance will be transformed to that of each winding to detect OCF. Then the voltage disturbance is combined with electrical position to locate the faulty switch.
AB - Dual Redundancy Permanent Magnet Synchronous Motor (DR-PMSM) has been widely used in the aviation electrical actuation system, the two sets of windings of DR-PMSM are independently driven by two inverters with isolated bus. When one set of winding or inverter fails, the other set of winding and inverter can work normally. However, the two sets of windings of DR-PMSM share one stator, which leads to strong coupling between the two sets of windings. In order to realize open-circuit fault (OCF) diagnosis of DR-PMSM, voltage disturbance observer of decoupled virtual current loops is designed. The voltage disturbance is observed with four luenberger observers of virtual current loops, the estimated voltage disturbance will be transformed to that of each winding to detect OCF. Then the voltage disturbance is combined with electrical position to locate the faulty switch.
KW - decoupling control
KW - dual redundancy permanent magnet synchronous motor(DR-PMSM)
KW - open circuit fault diagnosis
KW - virtual current loop
KW - voltage disturbance observer
UR - https://www.scopus.com/pages/publications/85179508307
U2 - 10.1109/IECON51785.2023.10311750
DO - 10.1109/IECON51785.2023.10311750
M3 - 会议稿件
AN - SCOPUS:85179508307
T3 - IECON Proceedings (Industrial Electronics Conference)
BT - IECON 2023 - 49th Annual Conference of the IEEE Industrial Electronics Society
PB - IEEE Computer Society
T2 - 49th Annual Conference of the IEEE Industrial Electronics Society, IECON 2023
Y2 - 16 October 2023 through 19 October 2023
ER -