Skip to main navigation Skip to search Skip to main content

Occurrence and partitioning of brominated flame retardants (BFRs) in indoor air and dust: a 15-month case study in a test home

  • Jia Qi Guo
  • , Yong feng Li
  • , Li Yan Liu*
  • , Chun Yan Huo
  • , Yu Sun
  • , Wan li Ma
  • , Zi feng Zhang
  • , Yi Fan Li
  • *Corresponding author for this work
  • School of Environment, Harbin Institute of Technology
  • Harbin Institute of Technology
  • University Corporation for Polar Research
  • College of Forestry, Northeast Forestry University
  • IJRC-PTS-NA

Research output: Contribution to journalArticlepeer-review

Abstract

Ten polybrominated diphenyl ethers (PBDEs) and 16 novel brominated flame retardants (NBFRs) were measured in air and dust samples collected in a test home in Harbin, China, from January 2017 to June 2018. The PBDE and NBFR concentrations in indoor air were in the ranges of 0.598–14.5 pg m−3 and 9.28–686 pg m−3, respectively. The ranges of the PBDE and NBFR concentrations in indoor dust were 221–1060 ng g−1 and 71.9–1160 ng g−1, respectively. Brominated flame retardant (BFR) concentrations in indoor air were affected by the temperature, relative humidity (RH), and ventilation. The BFR concentrations in indoor dust did not show temperature dependence. All dust samples were sieved into 6 size fractions (F1–F6: 1000–2000 μm, 500–1000 μm, 250–500 μm, 125–250 μm, 63–125 μm, and < 63 μm). The mass percentage of BFRs in F6 was the highest. The BFR concentrations did not increase constantly with a particle size decrease, and the concentrations in F2 were higher than those in F3. The partitioning behavior of BFRs illustrates that the dust-air partitioning coefficient approximately approached equilibrium within F5, F6, and the total dust fraction (FA) in the test home when logKOA was between 9.1 and 11.32. Air-dust fugacity fractions were calculated, and the results suggested that most of the BFRs were mainly transferred from air to dust in the indoor environment for F1–F6.

Original languageEnglish
Pages (from-to)35126-35136
Number of pages11
JournalEnvironmental Science and Pollution Research
Volume27
Issue number28
DOIs
StatePublished - 1 Oct 2020

Keywords

  • Dust-air exchange
  • Influence factors
  • NBFRs
  • PBDEs
  • Particle size
  • Source analysis

Fingerprint

Dive into the research topics of 'Occurrence and partitioning of brominated flame retardants (BFRs) in indoor air and dust: a 15-month case study in a test home'. Together they form a unique fingerprint.

Cite this