Skip to main navigation Skip to search Skip to main content

Numerical simulation of the influence of over fire air position on the combustion in a single furnace boiler with dual circle firing

  • Hiu Liu*
  • , Nana Xin
  • , Qingxi Cao
  • , Long Sha
  • , Dezhi Sun
  • , Shaohua Wu
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

The Computational fluid dynamics (CFD) code PHOENICS is applied to simulate and evaluate the combustion process within the furnace of a 1,000 MW dual circle tangential firing single furnace lignite-fired ultra supercritical (USC) boiler. The dependence on overfire air (OFA) positioning on the combustion process is studied. The results show that the highest temperature appears on the upside of the burner zone close to the front wall, and the high temperature zone rises with elevated OFA positions. However, the temperature field distributions are similar despite differing OFA positions. The char content near the rear wall is higher than that near the front wall, and below the furnace arch, coal particles concentrate towards the front wall. Also with elevated OFA positions, nitrogen oxide (NOx) concentrations at the outlet fall, but char content increases. In regard to NOx emission and char burnout, the suggested optimal distance from the OFA center to the center of the uppermost primary air nozzle should be 6 meters.

Original languageEnglish
Pages (from-to)1137-1143
Number of pages7
JournalKorean Journal of Chemical Engineering
Volume26
Issue number4
DOIs
StatePublished - 2009
Externally publishedYes

Keywords

  • Combustion
  • Dual Circle Tangential Firing
  • NO
  • Numerical Simulation
  • OFA

Fingerprint

Dive into the research topics of 'Numerical simulation of the influence of over fire air position on the combustion in a single furnace boiler with dual circle firing'. Together they form a unique fingerprint.

Cite this