Skip to main navigation Skip to search Skip to main content

Non-contact and non-destructive analysis of the quality of phenolic resin by near-infrared spectroscopy

  • Y. Dong*
  • , S. Y. Qu
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

The traditional analytical methods used to determine phenolic resin are slow and produce environmentally unfriendly waste. In this work, near-infrared (NIR) spectroscopy has been applied for resin content of phenolic resins. The partial least-squares regression was used to develop the calibration model of the resin content. Eight samples were withdrawn at different time stages for analysis with the proposed quantitative models; the data thus obtained were compared with those provided by reference methods. The maximal predicted error and the standard deviation of the differences were 0.96% and 0.51% for resin content. The results of the paired t test revealed that there was no significant difference between the NIR method and the reference method. NIR spectroscopy is an effective choice for the accurate, expeditious analyzing quality of phenolic resin.

Original languageEnglish
Pages (from-to)302-304
Number of pages3
JournalJournal of Testing and Evaluation
Volume40
Issue number2
DOIs
StatePublished - Mar 2012
Externally publishedYes

Keywords

  • NIR spectroscopy
  • Partial least-squares regression
  • Phenolic resin

Fingerprint

Dive into the research topics of 'Non-contact and non-destructive analysis of the quality of phenolic resin by near-infrared spectroscopy'. Together they form a unique fingerprint.

Cite this