Skip to main navigation Skip to search Skip to main content

Multiplexed electrochemical nucleic acid sensor based on visible light-mediated metal-free thiol-yne click reaction for simultaneous detection of different nucleic acid targets

  • Jinlong Fan
  • , Hanlin Gong
  • , Fan Wang
  • , Li Wang
  • , Yongsheng Yu
  • , Danqing Liu*
  • , Weiwei Yang*
  • *Corresponding author for this work
  • Harbin University of Science and Technology
  • School of Chemistry and Chemical Engineering, Harbin Institute of Technology
  • Northeast Agricultural University

Research output: Contribution to journalArticlepeer-review

Abstract

Simultaneous detection of multiple tumor biomarkers with a simple and low-cost assay is crucial for early cancer detection and diagnosis. Herein, we presented a low-cost and simple assay for multiplexed detection of tumor biomarkers using a spatially separated electrodes strategy. The sensor is fabricated based on a metal-free thiol-yne click reaction, which is mediated by visible light, on commercially available indium tin oxide (ITO) electrodes. Four biomarkers, including p53 DNA, Brca2 DNA, K-ras DNA, and MicroRNA-204 RNA, were used as model analytes, and the corresponding oligonucleotide probes were modified on the desired electrode units sequentially with 530 nm irradiation light in the presence of photosensitizer Eosin Y. By this visible light-mediated coupling reaction, oligonucleotide probe densities of up to 9.2 ± 0.7 × 1010 molecules/cm2 were readily obtained on the ITO electrode surface. The proposed multiplexed E-NA sensor could detect four different nucleic acid targets concurrently without crosstalk among adjacent electrodes and was also successfully applied for detecting targets in a 20% fetal calf serum sample. The detection limits for p53 DNA, Brca2 DNA, K-ras DNA, and MicroRNA-204 RNA were 0.72 nM, 0.97 nM, 2.15 nM, and 1.73 nM, respectively. The developed approach not only has a great potential for developing cost-effective biosensors on affordable substrates for nucleic acid target detection, but also be easily extended to detect other targets by modifying the specific oligonucleotide probes anchored on the electrode.

Original languageEnglish
Article number125856
JournalTalanta
Volume273
DOIs
StatePublished - 1 Jun 2024
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Indium tin oxide electrodes
  • Multiplexed assay
  • Nucleic acids detection
  • Thiol-yne click reaction
  • Visible light irradiation

Fingerprint

Dive into the research topics of 'Multiplexed electrochemical nucleic acid sensor based on visible light-mediated metal-free thiol-yne click reaction for simultaneous detection of different nucleic acid targets'. Together they form a unique fingerprint.

Cite this