Skip to main navigation Skip to search Skip to main content

Multiplexed detection of biomarkers using a microfluidic chip integrated with mass-producible micropillar array electrodes

  • Chaozhan Chen
  • , Bin Ran
  • , Bo Liu
  • , Xiaoxuan Liu
  • , Ziteng Zhang
  • , Yan Li
  • , Hongchun Li
  • , Minbo Lan
  • , Yonggang Zhu*
  • *Corresponding author for this work
  • Harbin Institute of Technology
  • Harbin Institute of Technology Shenzhen
  • Shenzhen Third People’s Hospital
  • East China University of Science and Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Quantifying multiple biomarkers with high sensitivity in tiny biological samples is essential to meet the growing demand for point-of-care testing. This paper reports the development of a novel microfluidic device integrated with mass-producible micropillar array electrodes (μAEs) for multiple biomarker detections. The μAE are mass-fabricated by soft lithography and hot embossing technique. Pt–Pd bimetallic nanoclusters (BNC) are modified on the surface of μAEs by constant potential (CP)/multi-potential step (MPS) electrodeposition strategies to improve the electroanalytical performance. The experimental result displays that Pt–Pd BNC/μAEs have good sensitivity enhancement compared with bare planar electrodes and bare μAEs, the enhancement being 56.5 and 9.5 times respectively, from the results of the H2O2 detection. Furthermore, glucose, uric acid and sarcosine were used as model biomarkers to show the biosensing capability with high sensitivity. The linear range and LOD of the glucose, uric acid and sarcosine detection are 0.1 mM–12 mM, 10 μM–800 μM and 2.5 μM–100 μM, 58.5, 3.4 and 0.4 μM, respectively. In particular, biosensing chips show wide linear ranges covering required detection ranges of glucose, uric acid and sarcosine in human serum, indicating the developed device has great potential in self-health management and clinical requirements.

Original languageEnglish
Article number341450
JournalAnalytica Chimica Acta
Volume1272
DOIs
StatePublished - 1 Sep 2023
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Biomarker detection
  • Electrochemical detection
  • High sensitivity
  • Mass-producible micropillar array electrode

Fingerprint

Dive into the research topics of 'Multiplexed detection of biomarkers using a microfluidic chip integrated with mass-producible micropillar array electrodes'. Together they form a unique fingerprint.

Cite this