Abstract
By analyzing the characterization way for flue gas humidity in gas-liquid regions of a spray dryer, a multipoint synchronous data acquisition wet-bulb temperature measuring set was developed to study the measurement of temperature-humidity fields. Results show that within the range of dry-bulb temperature from 90°C to 120°C and wet-bulb temperature from 40°C to 60°C, variation of flue gas humidity can be qualitatively characterized by the wet-bulb temperature, which will be kept relatively stable for 30-40s after humidifying performance completed; the closer the humidifying water temperature getting to the wet-bulb temperature, the less the measurement error will be; the results of multi-point measurement agree well with that of single-point measurement in both the dense and sparse liquid phase regions; the liquid phase distribution characteristics of measured section can be qualitatively obtained by comparing the temperature of naked thermocouple with that of wet-bulb.
| Original language | English |
|---|---|
| Pages (from-to) | 1041-1046 |
| Number of pages | 6 |
| Journal | Dongli Gongcheng/Power Engineering |
| Volume | 29 |
| Issue number | 11 |
| State | Published - Nov 2009 |
Keywords
- Dry-bulb and wet-bulb
- Humidity measurement
- Liquid phase distribution
- Liquid-gas region
- Spray drying
- Thermocouple
Fingerprint