This paper presents a six-step mode-combined field-weakening control scheme to improve the maximum output torque of induction motor (IM) in the voltage-extension region. Compared with the conventional inscribed circle and hexagon methods, the proposed six-step mode method can increase the utilization of dc-link voltage, leading to extended maximum output torque capability. However, the six-step mode operation will inevitably result in torque ripple and current harmonic. To figure out the quantitative relation between the torque extension and ripple, an 'equivalent-circuit'-based method is proposed for theoretical torque analysis in six-step mode. To cut off the main current harmonic (sixth harmonic), a second-order generalized integrator based band-stop filter is designed for the feedback current in the current loop. The designed filter can achieve IM stable operation in a six-step mode without affecting the bandwidth of the current loop. The experimental results from a 3.7-kW IM setup verify the effectiveness of the proposed scheme.

Original languageEnglish
Article number8600714
Pages (from-to)9129-9138
Number of pages10
JournalIEEE Transactions on Industrial Electronics
Volume66
Issue number12
DOIs
StatePublished - Dec 2019
Externally publishedYes

Keywords

  • Field-weakening control
  • induction motor (IM) drives
  • second-order generalized integrator (SOGI) based band-stop filter
  • six-step mode
  • torque analysis and extension