Skip to main navigation Skip to search Skip to main content

Linearized Minimum Current Stress Modulation Scheme of Single-Phase Bidirectional DAB AC-DC Converters

  • Dongxin Guo
  • , Panbao Wang*
  • , Chunguang Ren
  • , Josep M. Guerrero
  • *Corresponding author for this work
  • School of Electrical Engineering and Automation, Harbin Institute of Technology
  • Taiyuan University of Technology
  • Aalborg University

Research output: Contribution to journalArticlepeer-review

Abstract

In this article, the detailed steps for the derivation of linearized minimum current stress modulation scheme for single-phase bidirectional and isolated dual active bridge ac-dc converters is presented. In order to reduce the current stress of the converter, a Lagrange multiplier method scheme is designed to obtain the control coordinates constraint on the minimum value of the current stress. Compared with the conventional minimum current stress control scheme, the proposed scheme realizes the linearization of power control, which significantly reduces the complexity of the controller algorithm. Moreover, the synchronous inverter control applied to the back-stage full-bridge is designed. Thus, the single stage power conversion is realized and the converter topology is electrolytic capacitorless, which promote the improvement of system reliability and power density. The impact of the zero-voltage switching (ZVS) scheme is analyzed in detail, and the adaptive-ZVS scheme for less system loss is selected. Finally, experimental results confirm the validity and feasibility of the proposed control scheme.

Original languageEnglish
Pages (from-to)12410-12420
Number of pages11
JournalIEEE Transactions on Industrial Electronics
Volume70
Issue number12
DOIs
StatePublished - 1 Dec 2023
Externally publishedYes

Keywords

  • Dual active bridge (DAB) ac-dc converter
  • linearized control
  • minimum current stress (MCS)
  • single-stage power transmission
  • soft-switching

Fingerprint