Skip to main navigation Skip to search Skip to main content

Learning-Based Rapid Phase-Aberration Correction and Control for Robot-Assisted MRI-Guided Low-/High-Intensity Focused Ultrasound Treatments

  • Jing Dai
  • , Xiaomei Wang
  • , Bohao Zhu
  • , Liyuan Liang
  • , Hing Chiu Chang
  • , James Lam
  • , Xiaochen Xie*
  • , Ka Wai Kwok*
  • *Corresponding author for this work
  • The University of Hong Kong
  • Multi-Scale Medical Robotics Center
  • Chinese University of Hong Kong
  • Harbin Institute of Technology
  • University of Duisburg-Essen

Research output: Contribution to journalArticlepeer-review

Abstract

Magnetic resonance imaging (MRI)-guided focused ultrasound (MRg-FUS) is an effective and noninvasive procedure for treating diseases such as neurological disorders. Phase adjustment on ultrasound transducers can only achieve a limited focal-spot steering range. When treating large abdominopelvic targets, mechanical adjustment on the transducers' position and orientation is the prerequisite for enlarging the steering range. Therefore, we previously designed an MRI-guided robot to manipulate the transducers to offer sufficient focal-spot movement range. This could provide more modulation solutions to constructive ultrasound interference. However, full-wave ultrasound propagation inside a patient's heterogeneous abdominal media is complex and nonlinear, posing significant challenges in ultrasound modulation and beam motion control. Here, we propose a novel learning-based phase-aberration correction and model-free control framework for robot-assisted MRg-FUS treatments. The correction policy guarantees rapid aberration compensation within 5.0 ms. Submillimeter refocusing accuracy is achieved in both the liver (0.32 mm) and pancreas (0.51 mm), meeting clinical requirements for focal targeting. Our controller can accommodate nonlinear phase actuation with fast convergence (< 5.7 ms) and ensure accurate positional tracking with a mean error of 0.26 mm, without prior knowledge of inhomogeneous media. Compared with the conventional model-based method, it contributes to 61.77%–70.39% mean error reduction without requiring model parameter tuning.

Original languageEnglish
Pages (from-to)3935-3951
Number of pages17
JournalJournal of Field Robotics
Volume42
Issue number7
DOIs
StatePublished - Oct 2025
Externally publishedYes

Keywords

  • MRI-guided robotic platform
  • high-intensity focused ultrasound
  • learning-based control
  • low-intensity focused ultrasound
  • machine learning
  • magnetic resonance imaging
  • phase-aberration correction

Fingerprint

Dive into the research topics of 'Learning-Based Rapid Phase-Aberration Correction and Control for Robot-Assisted MRI-Guided Low-/High-Intensity Focused Ultrasound Treatments'. Together they form a unique fingerprint.

Cite this