Skip to main navigation Skip to search Skip to main content

Investigation of Indoor Airborne Bacteria in the Severe Cold Region in China: Genera, Levels, and the Influencing Factors of Concentration

  • Xiaojian Duan
  • , Chao Shen*
  • , Guozheng Chen
  • , Xi Deng*
  • , Phil Jones
  • *Corresponding author for this work
  • Harbin institute of technology
  • The University of Hong Kong
  • Cardiff University

Research output: Contribution to journalArticlepeer-review

Abstract

In regions experiencing severe cold, inadequate ventilation during winter months often leads to increased concentrations of indoor pollutants. While there have been several studies on indoor particulate matter and inorganic pollutants in such regions, bioaerosol pollution has not been as extensively investigated. This study examines the indoor bioaerosol situation in a university located in one of the severe cold regions in China, focusing on bacteria as a representative pollutant. It investigated random samples of an office and a dormitory (including washrooms) and spanned heating and nonheating periods. The findings indicated that bacterial abundance in the dormitory and office was approximately equivalent. The predominant airborne bacterial communities identified were Proteobacteria, Bacteroidota, Actinobacteriota, Firmicutes, and Myxococcota. Opening windows effectively reduced bacterial concentrations during both heating and nonheating periods. When windows remained closed, bacterial concentrations exceeded the standard by 9.1% during the nonheating period and by 14.3% during the heating period. Furthermore, temperature and relative humidity influenced bacterial particle size, activity, and consequently, aerosol concentrations. In the office, the highest percentage of bioaerosols was observed in particle sizes <1.1 and 1.1-2.1 μm, with smaller percentages observed in other particle sizes. Conversely, the percentage of particle sizes 2.1-3.3 μm in the dormitory was higher. The highest bacterial aerosol concentrations were detected in the morning in both the dormitory and office, during heating and nonheating periods. Bacterial concentrations in the office were lower on weekends than on weekdays, whereas in the dormitory, concentrations were higher on weekends than on weekdays. The above results indicate that indoor bacterial aerosol pollution is serious in winter in severe cold regions, which needs more attention.

Original languageEnglish
Article number8813703
JournalIndoor Air
Volume2024
DOIs
StatePublished - 2024
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • bacterial concentration
  • indoor air quality
  • severe cold region
  • space heating
  • university dormitory and office

Fingerprint

Dive into the research topics of 'Investigation of Indoor Airborne Bacteria in the Severe Cold Region in China: Genera, Levels, and the Influencing Factors of Concentration'. Together they form a unique fingerprint.

Cite this