Skip to main navigation Skip to search Skip to main content

Interference effects on the wind loads and wind-induced responses of parallel-arranged rectangular-planed air-supported membrane structures

  • Zhaoqing Chen*
  • , Chao Wei
  • , Liang Yin
  • , Ning Su
  • , Junbin Zhao
  • , Yue Wu
  • *Corresponding author for this work
  • Northeast Electric Power University
  • Ltd.
  • Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

In many practical projects, two air-supported membrane structures are parallel-arranged. The interference effects of parallel-arranged rectangular-planed air-supported membrane structures are important in the wind-resistant design. In order to address this issue, the wind pressures on isolated and parallel-arranged structures are obtained through pressure measurement wind tunnel tests. The wind-induced responses are calculated via nonlinear dynamic time–history analysis. Consequently, the interference effects on wind loads and wind-induced responses are analyzed. The results show that the wind suctions of downstream structures are amplified by the interferences of parallel-arranged structures particularly under oblique wind directions. The mean wind loads on the most disturbed zone are amplified up to about 65 %. The interference characteristics of wind-induced displacement are basically similar to mean wind loads. The membrane stresses and cable forces are significantly interfered only in oblique wind directions, which are amplified up to about 15 % in all zones of downstream structures. The strongest interference effects can be observed with a spacing-span ratio of 0.2 when the wind direction is oblique or parallel to the gap between neighboring structures. The interference factors for zones are provided to analyze the interference characteristics. In addition, recommendation values of the overall response interference factors are summarized for design reference. The overall response interference factors for displacement, membrane stress, and cable force should be considered as 1.21, 1.33, and 1.20, respectively.

Original languageEnglish
Article number111572
JournalThin-Walled Structures
Volume197
DOIs
StatePublished - Apr 2024

Keywords

  • Air-supported membrane structure
  • Interference effect
  • Wind load
  • Wind tunnel test
  • Wind-induced response

Fingerprint

Dive into the research topics of 'Interference effects on the wind loads and wind-induced responses of parallel-arranged rectangular-planed air-supported membrane structures'. Together they form a unique fingerprint.

Cite this