Abstract
This paper studied the Ne-like argon 46.9nm laser pumped by capillary discharge through experiments. In the experiment, adverse influence of the inherent pre-pulse generated by Blumlein transmission line of the capillary discharge setup on arising and stable output of soft X-ray laser was observed. In order to remove this influence, the method of installing a switch and a capacitor for insulating the inherent pre-discharge pulse is proposed. The experimental results show that the method can insulate the inherent pre-discharge pulse efficiently and the discharge setup reaches stabilization of operation. On the basis of this, the laser spike of Ne-like argon 46.9nm has been observed and improved.
| Original language | English |
|---|---|
| Pages (from-to) | 106-109 |
| Number of pages | 4 |
| Journal | Guangdian Gongcheng/Opto-Electronic Engineering |
| Volume | 33 |
| Issue number | 3 |
| State | Published - Mar 2006 |
Keywords
- Blumlein transmission line
- Capillary discharge
- Inherent pre-pulse
- Soft X-ray laser
- X-ray optics
Fingerprint
Dive into the research topics of 'Influence of the inherent pre-pulse of Blumlein transmission line on soft X-ray laser pumped by capillary discharge'. Together they form a unique fingerprint.Cite this