Skip to main navigation Skip to search Skip to main content

Influence of reference temperature on the thermal stress of slag-layer cooling in an atmospheric entrained-flow gasifier with high-speed circulating gasification agent

  • Haopeng Wang
  • , Zhichao Chen*
  • , Xiaoyan Zhang
  • , Zhengqi Li
  • , Neng Fang
  • , Xiaoying Liu
  • *Corresponding author for this work
  • School of Energy Science and Engineering, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

A slag slayer can protect the membrane wall in an entrained-flow gasifier. Maintaining a certain thickness of slag layer is particularly important for allowing an entrained-flow gasifier to operate steadily. Thermal stress is a major cause for a slag layer to break. This study aims to provide a numerical model that accurately represents the variation of thermal stress in the cooling slag layer in a novel entrained-flow gasifier. Based on experimental data from an industrial-sized atmospheric entrained-flow gasifier with high-speed circulating gasification agent, the thermal stresses owing to cooling are simulated numerically using transient thermal analysis. Creep relaxation is taken into consideration in the model. A continuous distribution of reference temperature based on that at the onset of cooling is applied to the numerical model. The results indicate that the thermal stresses in the slag layer are tensile during cooling, and that the von Mises stress increases. The von Mises stress appears to peak (at 72 MPa) near the initial liquid–solid interface at the end of the cooling process, which is therefore where the slag layer is most likely to crack or even be shed. The numerical model is also calculated with a fixed distribution of reference temperature by way of comparison. In that case, the von Mises stress in the initial solid slag layer decreases during cooling, which is contrary to common sense. The results show that the reference temperature used in the numerical model is crucial to the calculated thermal stress.

Original languageEnglish
Pages (from-to)446-454
Number of pages9
JournalApplied Thermal Engineering
Volume131
DOIs
StatePublished - 25 Feb 2018
Externally publishedYes

Keywords

  • Atmospheric entrained-flow gasifier
  • High-speed circulating gasification agent
  • Membrane wall
  • Slag layer
  • Thermal stress

Fingerprint

Dive into the research topics of 'Influence of reference temperature on the thermal stress of slag-layer cooling in an atmospheric entrained-flow gasifier with high-speed circulating gasification agent'. Together they form a unique fingerprint.

Cite this