Abstract
The impact of different types of line faults on the turbine-generator (T-G) shaft torsional dynamics in AC/DC power system, including three-phase to ground fault, one-phase to ground fault on sending end bus and receiving end bus are analyzed by PSCAD/EMTDC time-domain simulation. The simulation results shows that three-phase to ground fault on the sending end bus will cause shock electromagnetic torque vibration. The LP2 to GEN shaft torsional torque of T-G is most severe and special attention should be paid to.
| Original language | English |
|---|---|
| Title of host publication | 1st International Conference on Sustainable Power Generation and Supply, SUPERGEN '09 |
| DOIs | |
| State | Published - 2009 |
| Event | 1st International Conference on Sustainable Power Generation and Supply, SUPERGEN '09 - Nanjing, China Duration: 6 Apr 2009 → 7 Apr 2009 |
Publication series
| Name | 1st International Conference on Sustainable Power Generation and Supply, SUPERGEN '09 |
|---|
Conference
| Conference | 1st International Conference on Sustainable Power Generation and Supply, SUPERGEN '09 |
|---|---|
| Country/Territory | China |
| City | Nanjing |
| Period | 6/04/09 → 7/04/09 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- AC/DC power system
- Electromagnetic torque
- Shaft torsional torque
- System fault
Fingerprint
Dive into the research topics of 'Impact of system faults on turbine-generator shafts torsional dynamics in AC/DC power system'. Together they form a unique fingerprint.Cite this