Monitoring the concentration of antibiotics rapidly and cost-effectively is crucial for accurate clinical medication and timely identification of drug-induced illnesses. Here, we constructed a novel fluorescent assay kit to monitor Zavicefta, an effective antibiotic composed of avibactam (AVI) and ceftazidime (CFZ) to treat carbapenem-resistant gram-negative bacteria infections. AVI can emit fluorescence, but CFZ cannot. To enable simultaneous measurement of both in one kit, we designed molecularly imprinted polymer (MIP) modified quantum dots (QDs) for CFZ determination. MIPs have received significant attention as an artificial antibody due to their exceptional specificity for various targets, particularly drugs with small molecular weight. Under the excitation wavelength of 350 nm, the detection process involves a decrease in QDs’ fluorescence signal at 600 nm owing to the “gate effect” between MIP and CFZ and the internal filtration effect between CFZ and QDs. Simultaneously, a fluorescence emission characteristic peak at 420 nm for AVI emerges. In addition, to simplify the operation procedure and improve determination throughput, the detection agents were incorporated into a hydrogel and placed in a 96-well plate, enabling concurrent quantification of AVI and CFZ within the respective range of 80–1000 μM and 1–1000 μM. The developed assay kit successfully determined AVI and CFZ in human serums and therapeutic drug monitoring in a live rabbit model. Recoveries of AVI and CFZ were 92.7–114%, with relative standard deviations below 6.0%. Moreover, a smartphone was employed to read the fluorescence signals, which was beneficial for cost reduction and out-of-lab analysis. This study will deliver a pragmatic resolution to developing high-throughput assay kits for drug determination. Graphical Abstract: (Figure presented.)

Original languageEnglish
Article number675
JournalMicrochimica Acta
Volume191
Issue number11
DOIs
StatePublished - Nov 2024
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Antibiotics
  • Fluorescence assay kit
  • Hydrogel
  • Molecularly imprinted polymer
  • Quantum dot
  • Therapeutic drug monitoring

Fingerprint

Dive into the research topics of 'Hydrogel-based fluorescence assay kit for simultaneous determination of ceftazidime and avibactam'. Together they form a unique fingerprint.

Cite this