Skip to main navigation Skip to search Skip to main content

High-precision resistance calibrator error analysis and error distribution technology research

  • School of Electrical Engineering and Automation, Harbin Institute of Technology

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

In order to improve the high-precision resistance calibrator system, the error analysis model is established for each part of the hardware circuit and the calculation result of the output error of the resistance calibrator circuit is given in this paper. In order to further improve the precision of the resistance calibrator system, the error distribution scheme is proposed based on the principle of error distribution and feasibility analysis is also verified, which makes the resistance calibrator system meet the index and requirements.

Original languageEnglish
Title of host publicationProceedings of the 2017 12th IEEE Conference on Industrial Electronics and Applications, ICIEA 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1299-1303
Number of pages5
ISBN (Electronic)9781538621035
DOIs
StatePublished - 2 Jul 2017
Externally publishedYes
Event12th IEEE Conference on Industrial Electronics and Applications, ICIEA 2017 - Siem Reap, Cambodia
Duration: 18 Jun 201720 Jun 2017

Publication series

NameProceedings of the 2017 12th IEEE Conference on Industrial Electronics and Applications, ICIEA 2017
Volume2018-February

Conference

Conference12th IEEE Conference on Industrial Electronics and Applications, ICIEA 2017
Country/TerritoryCambodia
CitySiem Reap
Period18/06/1720/06/17

Keywords

  • error analysis
  • error distribution
  • high-precision resistance calibration

Fingerprint

Dive into the research topics of 'High-precision resistance calibrator error analysis and error distribution technology research'. Together they form a unique fingerprint.

Cite this