Skip to main navigation Skip to search Skip to main content

High order single step algorithm of pseudo-dynamic testing

  • School of Civil Engineering, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Due to the characteristics of unconditionally stable, good algorithm damping properties, no transcendental phenomenon, and Δt5 of truncation error, the high order single-step method had been successfully applied in nonlinear seismic response analysis and vibration controls. Based on the characteristics of the pseudo-dynamic testing and taking into account the permissible system accuracy, this paper introduces the concept of equivalent shear stiffness, and proposes the high order single-step algorithm of pseudo-dynamic testing. The feasibility and advantages of this algorithm are demonstrated by a comparison between numerical simulation results of the SDOF and 2 DOF structure with those of the three-level full-scale testing.

Original languageEnglish
Pages (from-to)14-19+26
JournalGongcheng Lixue/Engineering Mechanics
Volume25
Issue number11
StatePublished - Nov 2008
Externally publishedYes

Keywords

  • Equivalent shear
  • Full-scale model
  • High order single step method
  • Pseudo-dynamic testing method
  • Stiffness correction

Fingerprint

Dive into the research topics of 'High order single step algorithm of pseudo-dynamic testing'. Together they form a unique fingerprint.

Cite this