In this report, a sensitive quartz-enhanced photoacoustic spectroscopy (QEPAS) based hydrogen chloride (HCl) sensor using a quartz tuning fork (QTF) with a resonance frequency of 30.72 kHz was demonstrated for the first time. A fiber-coupled, continuous wave (CW), distributed feedback (DFB) diode laser emitting at 1.74 μm was employed as the excitation laser source. Wavelength modulation spectroscopy and a 2nd harmonic detection technique were used to reduce the sensor background noise. An acoustic micro-resonator (mR) was added to the QTF sensor architecture to improve the signal amplitude. For the reported HCl sensor system operating at atmospheric pressure, a 550 ppbv (parts per billion by volume) minimum detection limit at 5739.27 cm-1 was achieved when the modulation depth and the data acquisition time were set to 0.23 cm-1 and 1 s, respectively. The ppb-level detection sensitivity and robust design of the QEPAS technique makes it suitable for use in environmental monitoring and other applications.
| Original language | English |
|---|---|
| Pages (from-to) | 388-393 |
| Number of pages | 6 |
| Journal | Sensors and Actuators B: Chemical |
| Volume | 233 |
| DOIs | |
| State | Published - 5 Oct 2016 |