Abstract
The behaviour of axially loaded square and circular concrete-filled steel tube (CFST) columns when exposed to elevated temperatures is investigated in this paper. The fire resistance of this kind of composite tubes is calculated. Comparison of the square and circular columns in the fire resistance shows that, for columns with the same steel and concrete cross-section areas, the circular column has slightly better fire resistance than the square column.
| Original language | English |
|---|---|
| Pages (from-to) | 723-729 |
| Number of pages | 7 |
| Journal | Journal of Constructional Steel Research |
| Volume | 62 |
| Issue number | 7 |
| DOIs | |
| State | Published - Jul 2006 |
| Externally published | Yes |
Keywords
- Columns
- Composite
- Concrete
- Fire resistance
- Steel
- Tubes
Fingerprint
Dive into the research topics of 'Fire resistance of axially loaded concrete filled steel tube columns'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver