Abstract
In this paper, a multipoint counter electrode (MCE) sensor to be placed on the concrete surface for testing the corrosion rate of reinforcing steel was developed. Both the normal platform counter electrode and the MCE have been tested and compared in chloride-contaminated mortar, simulating a kind of marine circumstance. By using the simulation software ANSYS and comparing with the real weight loss of the steel during corrosion, the accuracy of the MCE has been evaluated.
| Original language | English |
|---|---|
| Article number | 6654257 |
| Pages (from-to) | 790-792 |
| Number of pages | 3 |
| Journal | IEEE Sensors Journal |
| Volume | 14 |
| Issue number | 3 |
| DOIs | |
| State | Published - Mar 2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 14 Life Below Water
Keywords
- Polarization resistance
- corrosion rate
- counter electrode
Fingerprint