Skip to main navigation Skip to search Skip to main content

Fault early warning method of nuclear power system condenser for icebreakers based on normal mode extraction

  • Xianling Li
  • , Zhiqiang Qiu
  • , Zhaoxu Chen
  • , Mo Tao
  • , Xingshuo Li
  • , Jinfu Liu
  • Science and Technology on Thermal Energy and Power Laboratory
  • Harbin Institute of Technology

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The condenser of nuclear power system for icebreaker is prone to scale and corrosion when it works in seawater environment, which affects the heat transfer performance and operation safety of the condenser. The traditional monitoring method of condenser tube wall cleanliness relying on terminal difference, thermal resistance and heat transfer coefficient is difficult to realize the fault early sensitive detection of condenser because of the influence of environmental and working conditions. Aiming at the characteristics of the condenser in the icebreaker nuclear power system, this paper reveals the influence law of disturbance factors on the condenser fault detection based on mechanism modeling and simulation, and develops fault detection and early warning method for condenser based on normal mode extraction. The robustness and validity of the proposed method and the sensitivity of detection of weak signs at the early stage of failure are verified by the actual operation data.

Original languageEnglish
Title of host publicationProceedings of the 27th International Conference on Nuclear Engineering, ICONE 2019 - "Nuclear Power Saves the World!"
PublisherAmerican Society of Mechanical Engineers (ASME)
ISBN (Electronic)9784888983051
StatePublished - 18 May 2019
Event27th International Conference on Nuclear Engineering: Nuclear Power Saves the World!, ICONE 2019 - Tsukuba, Ibaraki, Japan
Duration: 19 May 201924 May 2019

Publication series

NameInternational Conference on Nuclear Engineering, Proceedings, ICONE
Volume2019-May

Conference

Conference27th International Conference on Nuclear Engineering: Nuclear Power Saves the World!, ICONE 2019
Country/TerritoryJapan
CityTsukuba, Ibaraki
Period19/05/1924/05/19

Keywords

  • Condenser
  • Fault detection
  • Fault early warning
  • Normal mode extraction
  • Nuclear power system