Abstract
To study the connection method between reinforced bars of the precast concrete (PC) structure, 81 plug-in filling hole for lap-joint of steel bar sample tests were made, and the main factors, such as reinforced bar diameter, concrete strength and anchorage length etc. were considered during the tests. The test results indicated that the ultimate failure state of all the anchoring specimens were the external reinforced bar yielding or broken up by pulling, and the abnormal anchorage was not destroyed. When the basic anchoring length was reduced by 10% or even 20%, specimens still showed enough safety. Based on this, the basic anchoring length of plug-in filling hole for lap-joint of steel bar can be given as 0.8 la.
| Original language | English |
|---|---|
| Pages (from-to) | 28-31+36 |
| Journal | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology |
| Volume | 43 |
| Issue number | 4 |
| State | Published - Apr 2011 |
| Externally published | Yes |
Keywords
- Assembly structure
- Bond-slip behavior
- Housing industrialization
- Precast concrete structure
- Reinforcement anchorage & lapping
Fingerprint
Dive into the research topics of 'Experimental study on plug-in filling hole for steel bar anchorage of the PC structure'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver