Abstract

An experimental investigation to reduce the NOx emission during burning bituminous coal was carried out on a 670 t/h tangential pulverized coal firing furnace, with a technique combining horizontal bias combustion (HBC) burners in the primary combustion zone and separated over firing air (SOFA) nozzles above the highest secondary air nozzles. The influence mechanisms of this low NOx combustion system on NOx/CO emission and unburned carbon in fly ash have been measured and studied in situ. The tests indicate the amount of NOx emission can be decreased to less than 300 mg/m3 after adopting the reasonable distribution of secondary air, of which the OFA ratio is 30%. The concentration of NOx is lower than 400 mg/m3 in any case, and the lowest concentration can reach 250.84 mg/m3. Meanwhile, there is little effect on the unburned carbon content in fly ash which varies between 1.5% and 3%.

Original languageEnglish
Pages (from-to)8-14
Number of pages7
JournalZhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering
Volume28
Issue number17
StatePublished - 15 Jun 2008
Externally publishedYes

Keywords

  • Horizontal pulverized coal bias burner
  • NO emission
  • Over firing air
  • Pulverized coal fired boiler
  • Staging combustion technique
  • Unburned carbon content in fly ash