Abstract
This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source), which monitors the corrosion events in reinforced concrete (RC) structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event) releases electric energy; this is a novel idea proposed by this study. For accumulating the micro-corrosion energy, we integrate EPS with a COTS (Commercial Off-The-Shelf) energy-harvesting chip that recharges a supercapacitor. In particular, this study designs automatic energy management and adaptive transmitted power control polices to efficiently use the constrained accumulated energy. Finally, a set of preliminary experiments based on concrete pore solution are conducted to evaluate the feasibility and the efficacy of EPS.
| Original language | English |
|---|---|
| Pages (from-to) | 17414-17433 |
| Number of pages | 20 |
| Journal | Sensors |
| Volume | 13 |
| Issue number | 12 |
| DOIs | |
| State | Published - 17 Dec 2013 |
Keywords
- Corrosion monitoring
- Energy harvesting
- Wireless sensor
Fingerprint
Dive into the research topics of 'Events as power source: Wireless sustainable corrosion monitoring'. Together they form a unique fingerprint.Cite this