Skip to main navigation Skip to search Skip to main content

Enhancement of ultrasonic signal using a new design of Rayleigh-wave electromagnetic acoustic transducer

  • Lei Kang*
  • , Chao Zhang
  • , Steve Dixon
  • , Hui Zhao
  • , Samuel Hill
  • , Menghan Liu
  • *Corresponding author for this work
  • School of Electrical Engineering and Automation, Harbin Institute of Technology
  • University of Warwick

Research output: Contribution to journalArticlepeer-review

Abstract

The main disadvantage of electromagnetic acoustic transducers (EMATs) is their inefficiency in generating ultrasound. A new design of Rayleigh-wave EMAT is proposed with improved ultrasonic generation efficiency on non-ferromagnetic materials. The new EMAT's magnet is narrower than the meander-line coil used in the transducer and the coil itself has an uneven distribution of conductors. The principle of the new design is informed by finite element simulations, which show that the EMAT generates Rayleigh waves more efficiently by taking advantage of both horizontal and vertical magnetic fields of the magnet simultaneously. Experimental measurements verify that the maximum amplitude of the ultrasonic signal generated by the new design of EMAT working under a pulse-echo configuration has been enhanced by 90%, when compared to conventional designs.

Original languageEnglish
Pages (from-to)36-43
Number of pages8
JournalNDT and E International
Volume86
DOIs
StatePublished - 1 Mar 2017
Externally publishedYes

Keywords

  • EMAT
  • Electromagnetic acoustic transducer
  • Finite element simulation
  • Meander-line coil
  • Rayleigh wave

Fingerprint

Dive into the research topics of 'Enhancement of ultrasonic signal using a new design of Rayleigh-wave electromagnetic acoustic transducer'. Together they form a unique fingerprint.

Cite this